Set4Machine
Sets extended parameters specified by name and value for the machine / company.
Compatibility
Available as of IDEA version 10.0
Syntax
Set4Machine(paramName As String, paramValue As Object, [optional] location As Integer)
Parameters
paramName
Extended parameter name
paramValue
Extended parameter value. Can be one of the following types: Integer, String, Float, Date, Period, Object
location
[optional] Place where the databases are located(desktop or server).
UseContext = 0 represents the current behavior.
Desktop = 1 stores always on desktop (ignored on server).
Server = 2 stores data always on the server.
Remarks
If the parameter specified by paramName does not exist, all Save4XXX commands will create it.
If the parameter specified by paramName already exists, all Save4XXX commands will overwrite its value with a new one.
Example
Sub Main()
Dim mc As Object
Dim sc As Object
Dim parmeterizer As Object
Dim Period As Object
Dim startDate As Date
Dim toDate As Date
Set mc = SmartContext.MacroCommands
Set sc = mc.SimpleCommands
Set parameterizer = mc.GlobalParameters
'Setting string value for primary input file
parameterizer.Set4File SmartContext.PrimaryInputFile, "StringVal", "HaHaHa"
' Setting integer value for the audit folder
parameterizer.Set4AuditFolder "2015_0603", "IntVal", 100
' Setting string value for the audit folder
parameterizer.Set4AuditFolder "2014_0603", "StringVal", "Some String"
' Setting date value for the current project
startDate = DateSerial(2000, 1, 1)
parameterizer.Set4Project "DateTimeVal", startDate
' Setting period value for the current app workflow
toDate = DateSerial(3000, 1, 1)
Set Period = sc.CreatePeriod(startDate, toDate)
parameterizer.Set4App "PeriodVal", Period
' Setting float value for machine/company
parameterizer.Set4Machine "FloatVal", 123.45
End Sub